32026L0706#anx_VDirective (EU) 2026/706 of the European Parliament and of the Council

Annex V

Annex VI to Directive 2014/32/EU is amended as follows: (1) the part DEFINITIONS is amended as follows: (a) the first paragraph is replaced by the following: A thermal energy meter is an instrument designed to measure the energy which in a heat-exchange circuit is absorbed (cooling) and/or given off (heating) by a liquid called the thermal energy-conveying liquid.; (b) in the table, the fourth row is replaced by the following: Δθ=the temperature difference θin – θοut with Δθ ≥ 0 for heating and Δθ ≤ 0 for cooling; (2) the part SPECIFIC REQUIREMENTS is amended as follows: (a) point 1.1 is replaced by the following: 1.1. For the temperature of the liquid: θmax, θmin, for the temperature differences: Δθmax, Δθmin, subject to the following restrictions: Δθmax / Δθmin ≥ 10 with the exception of cooling applications; Δθmin is a whole number in the range of 1 K and 10 K.; (b) point 1.3 is replaced by the following: 1.3. For the flow rates of the liquid: qs, qp, qi, where the values of qp and qi are subject to the following restriction: qp / qi ≥ 5..